YASKAWA VS-616G5 Series Programming Manual page 86

Hide thumbs Also See for VS-616G5 Series:
Table of Contents

Advertisement

Section H: Control Circuit Terminals
H1 Digital Inputs
·Speed Search 1 and Speed Search 2 (Set value = 61 and 62)
Set values 61 and 62
n
n
are only available in the
open loop V/f and open
loop flux vector control
modes.
Searches from max
frequency when using
61, and set frequency
when using 62.
a = (L2-03) minimum
baseblock time
b = (L2-04) voltage
recovery time
= speed search decel
time
d = V/f pattern reduction
during speed search
· Energy Save Mode (Set value = 63)
After the energy savings input is closed and the output frequency is equal to or greater than (b8-02)
energy savings start frequency, the output voltage drops to the value in (b8-01) energy savings gain.
The output voltage increases and decreases based on L2-04 (voltage recovery time).
Run
Command
Energy
saving
command
Output
Frequency
Output
Voltage
86
Run
Command
Motor
RPM
Output
Frequency
a
d
Output
Voltage
c
b
Output
Current
Inverter is in
speed search
mode
V/f
c
Inverter is in
run mode
VS-616G5 Programming Manual
Open Loop
Flux
V/f w/PG
Vector
Vector
b3-02
(150% )
t
t
b8-02
t
b8-01
t

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents