Configuration for OPOS MSR Tester Program
3.
a.) Main screen buttons/items:
Button/Item
Device Name
Track Data
Clear
Open
Close
Message
b.) To get the track data using OPOS driver, follow the steps below:
Step 1: Enter the Device Name.
Step 2: Click Open button.
Step 3: Swipe the card to get the track data.
PA-3222 SERIES USER MANUAL
Description
(Combo box) Enter the device name that will be loaded to
the program.
(Text boxes) Show the raw and parsed track data.
(Button) Clear all the track data in the text boxes.
(Button) Open the OPOS driver and ready to get track
data.
(Button) Close the OPOS driver.
(Text box) Display the result message of running the
OPOS driver.
Chapter 4 Software Utilities
Page: 4-86