Ricoh FAX2000L Service Manual page 111

Hide thumbs Also See for FAX2000L:
Table of Contents

Advertisement

NCU PARAMETERS
Address
807FB1
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (high byte)
807FB2
Acceptable AI short protocol tone
(800Hz) detection upper frequency
lower limit (low byte)
807FB3
Detection time for 800 Hz AI short
protocol tone
807FB4
PSTN: Tx level from the modem
807FB5
PSTN: 1100 Hz tone transmission
level
807FB6
PSTN: 2100 Hz tone transmission
level
807FB7
PABX: Tx level from the modem
807FB8
PABX: 1100 Hz tone transmission
level
807FB9
PABX: 2100 Hz tone transmission
level
807FBA
Not used
to
807FBC
Modem turn-on level (incoming
807FBD
signal detection level)
807FDA
T.30 T1 timer
807FE0
Maximum wait time for post
bit 3
message
Function
4-44
Unit
BCD
If both addresses contain
(Hz)
FF(H), tone detection is
disabled.
20 ms
Factory setting: 360 ms
- dBm
Function 08 (parameter
01).
- N
- 0.5N
807FB4
807FB5
- N
- 0.5N
807FB4
807FB6
- dBm
- N
- 0.5N
807FB7
807FB8
- N
- 0.5N
807FB7
807FB9
Do not change these
settings.
-37-
0.5N
(dBm)
1 s
0: 12 s
1: Maximum wait time for
post message
1: 30 s
(EOP/EOM/MPS) can be
changed to 30 s.
Change this bit to "1" if
communication errors
occur frequently during
V.17 reception.
30 November, 1999
Remarks
(dB)
(dB)
(dB)
(dB)

Advertisement