30 November, 1999
Address
807F82
Bits 0 and 1 - Handset off-hook detection time
Bit
1
0
0
Other
Bits 2 and 3 - Handset on-hook detection time
Bit
3
0
0
Other
Bits 4 to 7 - Not used
Acceptable CED detection
807FA1
frequency upper limit (high byte)
807FA2
Acceptable CED detection upper
frequency upper limit (low byte)
807FA3
Acceptable CED detection
frequency lower limit (high byte)
807FA4
Acceptable CED detection upper
frequency lower limit (low byte)
807FA5
CED detection time
807FA6
Acceptable CNG detection
frequency upper limit (high byte)
807FA7
Acceptable CNG detection upper
frequency upper limit (low byte)
807FA8
Acceptable CNG detection
frequency lower limit (high byte)
807FA9
Acceptable CNG detection upper
frequency lower limit (low byte)
807FAA
Not used
807FAB
CNG on time
807FAC
CNG off time
807FAD
Number of CNG cycles required for
detection
807FAE
Not used
807FAF
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (high byte)
807FB0
Acceptable AI short protocol tone
(800Hz) detection upper frequency
upper limit (low byte)
Function
0
Setting
0
200 ms
1
800 ms
Not used
2
Setting
0
200 ms
1
800 ms
Not used
4-43
NCU PARAMETERS
Unit
Remarks
BCD
If both addresses contain
(Hz)
FF(H), tone detection is
disabled.
BCD
If both addresses contain
(Hz)
FF(H), tone detection is
disabled.
20 ms
Factory setting: 200 ms
± 20 ms
BCD
If both addresses contain
(Hz)
FF(H), tone detection is
disabled.
BCD
If both addresses contain
(Hz)
FF(H), tone detection is
disabled.
Do not change these
settings.
20 ms
Factory setting: 500 ms
20 ms
Factory setting: 200 ms
The data is coded in the
same way as address
807F33.
Factory setting: 23(H)
Do not change this setting.
BCD
If both addresses contain
(Hz)
FF(H), tone detection is
disabled.