Rep 9.3 Drum - Xerox 8830 Service Manual

Hide thumbs Also See for 8830:
Table of Contents

Advertisement

REP 9.3 Drum

Parts List on PL 9.2
WARNING
Switch off the Main Power Switch. Disconnect the
Power Cord.
Removal
NOTE: When the Drum is replaced, install a Cleaner
Blade Kit (REP 9.4).
1. Remove the Drum Assembly (REP 9.2).
8830
2. (Figure 1): Carefully place the Drum Assembly,
Gear Box down, in a safe place on the floor.
Figure 1. Securing the Drum Assembly
1/98
4-49
3. (Figure 2): Remove the Drum from the Shaft
Assembly.
2
Lift off the
Bearing/Plate
Assembly
lift the Drum
off the Shaft
Assembly
Figure 2. Removing the Drum from the
Shaft Assembly
4. If the Drum is being replaced, install a Cleaner
Blade Kit (REP 9.4).
5. Reassemble the Drum Assembly.
6.
Perform GP4 Drum Cleaning Enhancement
procedure.
7. Reinstall the Drum Assembly.
8. Perform the Electrostatic Series (ADJ 9.2).
REP 9.3

Hide quick links:

Advertisement

Table of Contents
loading