Xerox 8830 Service Manual page 246

Hide thumbs Also See for 8830:
Table of Contents

Advertisement

GP1 HVPS Checkout
The purpose of this checkout procedure is to
verify correct operation of the High Voltage
Power Supply.
NOTE:
Use the 26V RTN test point when
measuring all voltages. Failure to use this test
point can cause incorrect readings.
GP1 HVPS Checkout Procedure
Figure 1. Location of HVPS Test Points
Perform the voltage checks shown in Table 1.
Table 1. HVPS Voltage Checks
v-om
COM
Standby
Meter
Meter
Measured Voltage
Lead
Lead
26V RTN
26V
26.5 VDC
PIN 1
Less than 0.05 VDC
26V RTN
GRID V
N/A
26V RTN
26V RTN
Less than 0.05 VDC
DEW
TFR I
Less than 0.05 VDC
26V RTN
DET I
26V RTN
Less than 0.05 VAC
1/98
6-10
VIEW: REAR(TOP)
PHOTO #0030
In Print
Diagnos
Measured Voltage
tic Code
26.5 VDC
2.3 ± 0.05 VDC
N/A
-4.20 ± 0.05 VDC
0.6 ±0.1 VDC
[921-1]
1.0 VAC
[921-1]
8830