REP 4.1.7 Edge Registered Sensor

Parts List on PL 5.1
Removal
WARNING
Switch off the Scanner and disconnect the Power
Cord.
1. Remove the Exposure Lamp (REP 4.1.3).
2. Remove the Platen Glass (REP 4.1.5)
3. (Figure 1): Prepare to remove the Edge Registered Sensor.
4. (Figure 2): Remove the Edge Registered Sensor.
NOTE:
The string will be used to pull the sensor cable back through
the channel during reinstallation of the sensor.
Channel
Figure 1. Connector P6, Attaching the String
7356 SCANNER
B
Disconnect
Connector P6
A
Attach a string
at least 30 in.
(76 cm) long
to the sensor
cable
001044A-COB
B
Remove the
two screws
c
Remove the
sensor and cable.
Figure 2. Removing the Edge Registered Sensor
4/97
4-11
Edge
Registered
Sensor
91042A-COB
Cover the optical path slot
with paper to prevent the
screws from falling into the
scanner
REP 4.1.7