Sensor RAP

Initial Actions
This procedure can be used to check any
Sensor.
Ensure that the Sensor is not blocked.
Clean the Sensor surfaces before using
this procedure.
Procedure
Enter DIAGNOSTICS (General Procedures).
Enter code [xxxx] to test the Sensor (Refer to
appropriate BSD for the specific code). Block
the Sensor.
The Display toggles between [1] and [0].
Y
N
There is 4-1.4 -/+0.2 VDC at J1/P1 pin 1
of the PWB.
Y
N
There is 4-5 +/-0.3 VDC at J1/P1 pin
2 of the PWB.
Y
N
Switch off the power. There Is
less than 2 Ohms from J1/P1
pin 2 to the machine frame.
Y
N
I
Replace the PWB.
Disconnect J1.
There is less
than 2 Ohms from J1/P1 pin 2 to
the machine frame.
Y
N
Check the wire at J1/P1 pin 1
for a short circuit.
If the wire is good, replace the
Sensor.
Replace the PWB.
Check the wire at J1/P1 pin 2 for an
open circuit.
If the wire is good, replace the Sensor.
A B

Generic Sensor RAP

A B
There is +11.5 VDC at J1 pin 1 of the PWB.
Y N
I
Replace the PWB.
Check the wire at J1/P1 pin 1 for an open circuit.
If the wire is good, check the wire at J1/P1 pin 3
for an open circuit.
If the wire is good, replace the Sensor.
Block the Sensor. The Message Display indicates
HIGH.
Y
N
There is +11.5 VDC at J1 pin 1 of the PWB.
Y
N
Check the wire at J1/P1 pin 1 for a short circuit
to ground.
If the wire is good, replace the Sensor.
Replace the PWB.
The Sensor and its circuit appear to be operating norm-
ally, check the adjustment or alignment of the Sensor.