5. Remove the Roller transfer [8] from the Guide transfer [7].
6. Remove one SR5 [9].
7. Remove two screws [10] from the Guide transfer [7] and remove the Bracket guide TR F [11] and the
Bracket guide TR B [12].
[ 12 ]
[ 10 ]
NOTE
When you have replaced the Roller Transfer, be sure to reset the counter. See "3.9.1 When you replace
the fuser unit or transfer roller" on page 3-80 how to reset it.
[ 9 ]
[ 7 ]
5-46
[ 8 ]
[ 11 ]
[ 10 ]