Muratec MFX-3595 Field Engineering Manual page 164

Table of Contents

Advertisement

Unique Switch 01x : Transmission
Unique Switch 018 :
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
1
Factory use only
4
0
Disconnect the line when
the transmission speed falls
down under 7200 bps
0: No
1: Yes
3
0
Disconnect the line when
the transmission speed falls
down under 4800 bps
0: No
1: Yes
2
0
Factory use only
1
0
Factory use only
0
0
Transmission when disable to
detect first NSF in real time
transmission.
0: Retry to detect NSF
1: Transmit with the standard
Unique Switch 019 :
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
1
Number of redial times for
archive transmission
2
1
1
1
0
1
Adjust
protocol
Adjust
Usage/Comments
Determine if the machine disconnect the phone line
when the transmission speed fall down under 7200
bps.
Determine if the machine disconnect the phone line
when the transmission speed fall down under 4800
bps.
Determines the action when disable to detect first
NSF in real time transmission.
Usage/Comments
Switch 4 3 2 1 0
0 0 0 0
0 time
0 0 0 1
1 time
0 0 1 0
2 times
0 0 1 1
3 times
0 1 0 0
4 times
0 1 0 1
5 times
0 1 1 0
6 times
0 1 1 1
7 times
1 0 0 0
8 times
1 0 0 1
9 times
1 0 1 0
10 times
1 0 1 1
11 times
1 1 0 0
12 times
1 1 0 1
13 times
1 1 1 0
14 times
1 1 1 1
15 times (default)