Memory switch 00x : Dialer
Memory switch 005 :
Initial
bit
Setting
7
0
Factory use only
6
1
Ring signal detect time
5
1
4
0
3
0
Number of CI signal detec-
tion
0 : Detect 1 time
1 : Detect 2 times
2
0
Dual ring detection
1
0
Long ring detection
0 : No
1 : Yes
0
1
Frequency of the CI signal
0 : No
1 : Yes
Memory switch 006~ 009 : Factory use only
Adjust
Set the time that an incoming ring will not be detected after
hanging up.
Switch 654
Select the number of detection time of CI signal in the ringer
silent mode.
Incoming calls are answered according to this setting regard-
less of the number of rings chosen in the user settings.
When enabled, the machine is able to auto answer an incom-
ing ring with an off time of 120-60 ms.
Allows the machine to respond to an incoming ring if the ring
on time is longer than two seconds.
When disabled, the unit will not check the frequency of the in-
coming CI signal.
Usage / Comments
000
100 ms
001
200 ms
010
300 ms
011
400 ms
100
500 ms
101
600 ms
110
700 ms
111
800 ms