Machine Parameter 060
Initial
Switch
Setting
7
0
Mirror carriage standby
position adjustment
6
0
5
0
Adjusts the number of steps
4
0
from home sensor ON to
3
1
standby position
2
1
1
1
1 step = 2 / 600 dpi
0
1
Machine Parameter 061 ~ 064 — Factory use only
Machine Parameter 065
Initial
Switch
Setting
7
0
Background level adjustment
starting position
6
0
5
0
Adjusts the number of steps
4
0
from the home sensor OFF to
3
0
background level adjustment
2
0
starting position
1
0
0
0
1 step = 2 / 600 dpi
Adjust
(0.084 mm)
Adjust
(0.084 mm)
Usage/Comments
Switch
76543210
127 steps 01111111
:
00100000
:
00010000
:
00001000
:
00000000
:
10001000
:
10010000
:
10100000
:
-127steps
11111111
After the adjustment, please adjust machine param-
eter 033, 034, 038, and 039.
Usage/Comments
Switch
76543210
127 steps 01111111
:
00100000
:
00010000
:
00001000
:
00000000
:
10001000
:
10010000
:
10100000
:
-127steps
11111111
3-13
Settings
+10.67 mm
+2.69 mm
+1.34 mm
+0.67 mm
0 mm
-0.67 mm
-1.34 mm
-2.69 mm
-10.67 mm
Settings
+10.67 mm
+2.69 mm
+1.34 mm
+0.67 mm
0 mm
-0.67 mm
-1.34 mm
-2.69 mm
-10.67 mm