Advertisement

Unique Switch 05x : Printer
Unique Switch 053 :
Initial
Switch
Setting
7
0
Printer density adjustment.
6
0
5
0
4
0
3
1
2
0
1
0
0
0
Unique Switch 054 ~ 055 — Factory use only
Unique Switch 056 :
Initial
Switch
Setting
7
0
Enable paper with Letterhead
0: No
1: Yes
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
1
Factory use only
2
0
Factory use only
1
0
Reduce received fax in Letter
size
0: No
1: Yes
0
1
Factory use only
Unique Switch 057 :
Initial
Switch
Setting
7
0
Factory use only
6
0
Enable toner saving mode
0: Yes (enabled)
1: No (disabled)
5
0
Paper selection priority
0: Less margin
1: Same paper width
4
0
Factory use only
3
0
Factory use only
2
1
Factory use only
1
0
Factory use only
0
0
Factory use only
Unique Switch 058 ~ 059 — Factory use only
Unique Switch 06x — Factory use only
Adjust
Switch
Adjust
Set this switch to "1" when you want the machine
display "L.H(LTR)" for paper size.
Set this switch to "1" when you use A4 paper and
always receive Letter size faxes.
Adjust
3-66
Usage/Comments
76543210
Settings
00000000
Not available
00000001
Lightest
00000010
:
:
00000101
Standard
:
:
00001001
Darkest
00001010
Adopt "Standard"
: