Machine Parameter 037
Initial
Switch
Setting
7
0
Adjustment of the scanning
stretching and squeezing for
6
0
URADF.
5
0
(Vertical)
4
0
3
0
The plus setting stretches the
2
0
image data and the minus
1
0
setting squeezes it.
0
0
Each setting changes by
0.01%
Machine Parameter 038
Initial
Switch
Setting
7
1
Front side of document
6
0
5
0
Leading edge document
4
1
margin adjustment (URADF)
3
1
2
0
Adjusts the leading edge
1
1
margin from Document
0
1
Sensor 2 (DS2) to the start
of scanning the position.
1 step = 2 / 600 dpi
Adjust
Adjust
(0.084 mm)
Usage/Comments
Switch 76543210
bit
76543210
01111111
:
00010000
:
00000100
:
00000000
:
10000100
:
10010000
:
11111111
Usage/Comments
Switch
76543210
127 steps 01111111
:
00100000
:
00010000
:
00001000
:
00000000
:
10001000
:
10010000
:
10100000
:
-127 steps 11111111
3-9
Settings
+1.27%
+0.16%
+0.04%
0%
-0.04%
-0.16%
-1.27%
Settings
+10.67 mm
+2.69 mm
+1.34 mm
+0.67 mm
0 mm
-0.67 mm
-1.34 mm
-2.69 mm
-10.67 mm