Machine Parameter 093
Initial
Switch
Setting
7
0
6
1
Decurl unit
0: No
1: Yes (default)
5
0
Adjustment for timing to shift
paper.(MFX-3595 only)
4
0
3
0
You can use this mode when
2
0
Machine Parameter 93-6 is
1
0
"1".
0
0
Machine Parameter 094 ~ 259 — Factory use only
Machine Parameter 260
Initial
Switch
Setting
Factory use only
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
3
0
2
0
1
0
0
0
Paper loop volume
Machine Parameter 261 ~ 300 — Factory use only
Adjust
Set "1" when the machine has the decurl unit.
The control of shift sorting and paper feed differs
between machines with and without decurl unit.
When the roller leaves a mark on the back end of
the paper, increase the value.
When the machine ejects the paper without sorting,
decrease the value.
Switch 543210
bit
Adjust
Adjust the loop at the synchronizing roller.
More loop will correct paper skew, but thin paper may
jam easily.
Switch
3-16
Usage/Comments
Settings
543210
011111
+31 mm
:
010000
+16 mm
:
000100
+4 mm
:
000000
0 mm
:
100100
-4 mm
:
110000
-16 mm
:
111111
-31 mm
Usage/Comments
3210
Settings
1111
15 ms
0101
5 ms
0100
4 ms
0011
3 ms
0010
2 ms
0001
1 ms
0000
No adjustment