Mitsubishi MELDAS MDS-C1 Instruction Manual page 30

Ac servo/spindle
Table of Contents

Advertisement

3)
Keep the deviation of the sensor center and detection
gear center to ±0.25mm or less. If the center deviation
cannot be directly measured, set so that the dimension
from the sensor installing surface to the edge of the
detection gears is 22.5±0.25mm.
4)
Keep the deflection of the outer diameter, when the
detection gears are installed on the shaft, to 0.02mm or
less.
5)
To remove a detection gear fixed with shrinkage fitting,
use the screw holes opened in the axial direction for
pulling (two M5 screw holes or two M8 screw holes), or
push the end with a jig. Carry out this work carefully.
Applying excessive force when pulling out the gears
could cause the inner diameter of the detection gears to
deform.
6)
Before reusing detection gears which have been remove-
d, always measure the inner diameter dimensions, and
carefully check that the inner diameter is not deformed,
and that the sufficient tightening amount can be secured.
Do not reuse the detection gears if the inner diameter is
deformed, or if any abnormality such as damage to the
teeth is found.
7)
A notched fitting section and mounting screw hole are
provided on the machine as shown in the following
drawing. Contact the R section of the sensor installation
seat against this and, install the sensor. The outline dimensions of the notched fitting section
are shown in the following table.
Encoder part type
TS1860N2275
TS1860N2276
TS1860N2777
TS1860N2775
TS1860N2171
TS1860N2174
TS1860N2571
TS1860N2572
1. Installation
Installing the sensor section
Sensor installation seat's
R dimensions (mm)
R35.5
R45
R61
R112.5
1 - 18
Sensor installation surface
Sensor installation seat
Lead wire
16.5mm
22.5mm±0.25mm
First tooth
Installing the detection gears
Notched fitting section's
outer diameter (mm)
+0.200
ø71
+0.180
+0.200
ø90
+0.180
+0.200
ø122
+0.175
+0.200
ø225
+0.170

Hide quick links: