(2) Adjusting for feed forward control
When using feed forward control (high-speed high-accuracy control), the feed forward control must
be stopped (fwd_g =0) before adjusting the overshooting compensation. After adjusting the
overshooting compensation with normal control, set the overshooting compensation non-sensitive
zone (SV034 (SSF3)/bitC to F (ovsn) to 1 (2µm) and start up feed forward control.
If overshooting compensation is used during feed forward control, the overshooting will increase,
or protrusions could appear during arc cutting. This is because, when the NC is carrying out feed
forward (fwd) control, overshooting equivalent to the operation fraction unit occurs in the position
command, and the OVS compensation is recognized as a change in the command direction,
resulting in compensation in the reverse direction. This can be improved by setting the
overshooting compensation non-sensitive zone width.
If overshooting does not occur during normal control, and occurs only during feed forward control,
adjust the feed forward gain (fwd_g).
No.
Abbrev.
Parameter name
SV031
OVS1 Overshooting
compensation 1
SV042
OVS2 Overshooting
compensation 2
SV027
SSF1
Servo function
selection 1
SV034
SSF3
Servo function
selection 3
POINT
4. Servo Adjustment
Increase in increments of 1%, and find the value where overshooting does
not occur. The value is set in both the ± directions when OVS2 is set to 0.
Set to "0" as a standard.
Set this to change the compensation amount according to the direction.
F
E
D
aflt zrn2
afse
bit
Meaning when "0" is set
A
Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).
ovs
B
00: Overshooting compensation stop 10: Overshooting compensation type 2
01: Overshooting compensation type1 11: Overshooting compensation type 3
F
E
D
ovsn
bit
C
Set the non-sensitive band of the overshooting compensation type 3 in
increments of 2µm at a time.
D
ovsn
In the feed forward control, the non-sensitive band of the model position
E
droop is set, and overshooting of the model is ignored. Set to the
F
standard 2µm (0001).
When using feed forward control (high-speed high-accuracy control), stop the
feed forward control (fwd_g=0) before adjusting the overshooting
compensation. If overshooting occurs during subsequent feed forward control,
adjust the feed forward gain (fwd_g).
Explanation
C
B
A
9
8
7
ovs
lmc
omr zrn3
C
B
A
9
8
7
Explanation
4 - 26
Setting range
-1 to 100
(Stall [rated]
current %)
-1 to 100
(Stall [rated]
current %)
6
5
4
3
2
1
vfct
upc
vcnt
Meaning when "1" is set
6
5
4
3
2
1
os2 zeg
mohn has2 has1
0
0

Hide quick links: