No.
Abbr.
Parameter name
SP034 SFNC2* Spindle function 2
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.
3. Setup
<For MDS-C1-SP/SPH/SPX/SPHX>
F
E
D
C
B
bit
Meaning when set to 0
0
mtsl Special motor constant invalid
A general-purpose motor FV control
1 invm
invalid
2 mkch Coil switch function invalid
3 mkc2 Coil switch function 2 invalid
4
5
6
7
8
9
A
B
C
D
E
F
(Note 1) To validate bit3, NC side needs to be prepared.
(Note 2) Set 0 if there is no particular explanation for the bit.
<For MDS-C1-SPM>
F
E
D
C
B
bit
Meaning when set to 0
0
mtsl Special motor constant invalid
1 mk3c 3-step coil switch function invalid
2 mkch Coil switch function invalid
3 mkc2 Coil switch function 2 invalid
4
5
6
7
8
9
A
B
C
D
E
F
(Note 1) To validate bit3, NC side needs to be prepared.
(Note 2) Set 0 if there is no particular explanation for the bit.
3 - 60
Details
A
9
8
7
6
5
Meaning when set to 1
Special motor constant setting valid
A general-purpose motor FV control
valid
Coil switch function valid
Coil switch function 2 valid
(Turns ON simultaneously with bit2)
A
9
8
7
6
5
Meaning when set to 1
Special motor constant setting valid
3-step coil switch function valid
Coil switch function valid
Coil switch function 2 valid
(Turns ON simultaneously with bit2)
4
3
2
1
0
mkc2 mkch
invm mtsl
Standard
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
0
mtsl
mkc2 mkch mk3c
Standard
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0