Adjusting the spindle synchronous control

(1) Confirming the default parameters
Confirm that the parameters are correctly set according to the machine specifications. The
parameters are set with the following conditions for spindles used for synchronous control.
1) Position loop gain
The same value must be set for the spindle drive units used for synchronous control.
Spindle synchronous position loop gain
Spindle synchronous position loop gain 2 : SP189
Spindle synchronous position loop gain 3 : SP190
<Spindle parameters>
No.
Abbrev.
SP010
PGS
Spindle synchronous position loop gain
SP177 SPECS* Spindle synchronous specifications
SP178 VGSP* Spindle synchronous speed loop gain proportional term
SP179 VGSI* Spindle synchronous speed loop gain integral term
SP180 VGSD* Spindle synchronous speed loop gain delay advance term
SP181 VCGS* Spindle synchronous Target value of variable speed loop proportional gain
Spindle synchronous Change starting speed of variable speed loop
SP182 VCSS*
proportional gain
SP183
SYNV Spindle synchronous Sync matching speed
SP185
SINP
Spindle synchronous In-position width
SP186 SODR* Spindle synchronous Excessive error width (1pulse=0.088deg)
SP187 IQGS* Spindle synchronous Current loop gain magnification 1
SP188 IDGS* Spindle synchronous Current loop gain magnification 2
SP189
PG2S Spindle synchronous Position loop gain 2
SP190
PG3S Spindle synchronous Position loop gain 3
5. Spindle Adjustment
: SP010
Parameter name
5 - 32
Setting
Standard
Unit
range
value
rad/s
1 to 100
15
0000 to
HEX
0000
FFFF
0 to 1000
63
0 to 1000
60
0 to 1000
15
%
0 to 100
100
r/min
0 to 32767
0
r/min
0 to 1000
20
1/16 deg
1 to 2880
16
pulse
0 to 32767
32767
%
0 to 1000
100
%
0 to 1000
100
rad/s
0 to 999
0
rad/s
0 to 999
0