Mitsubishi MELDAS MDS-C1 Instruction Manual page 228

Ac servo/spindle
Table of Contents

Advertisement

(3) Adjusting the variable current loop gain
In most cases, problems will not occur when the default value is used. This loop gain must be
adjusted if fine vibration occurs while the spindle motor is rotating at a high speed. Adjust the
current loop gain at the high-speed range, so that the output current to the spindle motor is stable.
If fine vibration occurs at high-speed range
When speed fluctuates (is unstable) at high-speed range : Increase SP069 in increments of
No.
Abbr.
Parameter name
Target value of variable
SP069
VIGN*
current loop gain
5. Spindle Adjustment
Details
Set the magnification of current loop gain (torque
component and excitation component) for a change
ending speed defined in SP068 (VIGWB).
When this parameter is set to "0", the magnification is 1.
SP069×(1/16)-fold
1-fold
SP067
SP017 (TSP)
SP067
Maximum
(VIGWA)
motor speed
0 to 6000
0
6001 to 8000
5000
8001 or more
5000
5 - 18
: Decrease SP069 in increments of
approx. 8
approx. 8
Setting range Standard
Speed
SP068
SP017
SP068
SP069
(VIGWB)
(VIGN)
0
0
8000
45
10000
64
0 to 32767
0
(1/16-fold)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents