Mitsubishi MELDAS MDS-C1 Instruction Manual page 132

Ac servo/spindle
Table of Contents

Advertisement

M60S
Series
Abbrev.
Parameter name
No.
Orientation
3021
sori
rotation speed
Encoder gear ratio Set the gear ratio of the spindle to the encoder.
3022
sgear
Minimum rotation
3023
smini
speed
Spindle
connection
3024
sout*
Spindle encoder
3025
enc-on
Selection of coil in
3026
cs_ori
orientation mode
Selection of coil in
spindle
synchronous
mode
3027
cs_syn
L system tap cycle
spindle forward
3028
sprcmm
run/
reverse run M
command
Asynchronous tap
gear selection
3029
tapusel
Selection of
3030
mbsel *
magnetic bearings
Drive unit I/F
channel No.
(spindle)
3031
smcp_no *
Drive unit I/F
channel No.
(magnetic
3032
mbmcp_no *
bearing)
Parameters with an asterisk * in the abbreviation, such as sout*, are validated with the NC power turned ON again.
3. Setup
Set the spindle orientation rotation speed.
Set the rotation speed for when the spindle rotates at the constant
rotation speed.
Set the minimum rotation speed of the spindle.
If an S command instructs the rotation speed below this setting, the
spindle rotates at the minimum rotation speed set by this parameter.
Set the type of the spindle to be connected.
0: No connection with the spindle
1: Serial connection (bus)
2 to 5: Analog output
Set connection information of the spindle encoder.
0: No connection
1: Spindle connection (Spindle encoder connection check function
valid.)
2: Serial connection of encoder
0: Perform orientation using the coil selected when the orientation
command is issued.
1: Use coil L whenever the orientation command is issued.
0: The coil H/L is selected by the actual spindle motor rotation speed
(calculated from commanded rotation speed) when spindle
synchronous control starts. (The coil is not switched during
synchronous control. The control is carried out with the coil selected
at start.)
If the actual spindle motor rotation speed is less than SP020, the coil
L is selected, and if more than the value, the coil H is selected.
1: Use coil H whenever the spindle synchronous command is issued.
Set the M code of the spindle forward run/reverse run command.
High-order three digits:
The spindle forward run command's M code is
set.
Low-order three digits:
The spindle reverse run command's M code is
set.
Specify whether to use the tap rotation speed or maximum rotation
speed for the gear that is selected when an asynchronous tap command
is issued.
0: Tap rotation speed
1: Maximum rotation speed
This parameter is valid only when the M-function synchronous tap cycle
enable parameter (#1272 ext08 bit1) is ON.
Select whether to use magnetic bearings.
0: Magnetic bearings invalid
1: Magnetic bearings valid
Using a 4-digit number, set the drive unit interface channel No. and
which axis in that channel is to be used when connecting a spindle drive.
High-order two digits : Drive unit interface channel No.
Low-order two digits : Axis No.
When using the conventional fixed layout, set all axes to "0000".
Set "0000" when using an analog spindle.
Using a 4-digit number, set the drive unit interface channel No. and
which axis in that channel is to be used when connecting a magnetic
bearing unit.
High-order two digits : Drive unit interface channel No.
Low-order two digits : Axis No.
When using the conventional fixed layout, set all axes to "0000".
3 - 53
Details
Setting range
(Unit)
0 to 32767
(r/min)
0: 1/1
1: 1/2
2: 1/4
3: 1/8
0 to 32767
(r/min)
0 to 5
0 to 2
0/1
0/1
0 to 999999
0/1
0/1
0000
0101 to 0107
0201 to 0207
0000
0101 to 0107
0201 to 0207

Hide quick links: