Mitsubishi MELDAS MDS-C1 Instruction Manual page 143

Ac servo/spindle
Table of Contents

Advertisement

No.
Abbr.
Parameter name
SP037 SFNC5* Spindle function 5
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.
3. Setup
<For MDS-C1-SPM>
F
E
D
C
B
bit
Meaning when set to 0
0 enco Encoder orientation invalid
1
2
plgo PLG orientation invalid
3
4
5
6
7
No-signal detection type
8 nosg
(Always monitoring)
9 nsno No-signal detection valid
A
B
C
D
E
F
(Note 1) For bit0 to 2, do not set two bits or more to "1" at the same time.
(Note 2) Set 0 if there is no particular explanation for the bit.
3 - 64
Details
A
9
8
7
6
5
nsno nosg
Meaning when set to 1
Encoder orientation valid
PLG orientation valid
Monitoring only in position loop or
orientation-mode
No-signal detection invalid
4
3
2
1
0
plgo
enco
Standard
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0