Inspections

Periodic inspection of the following items is recommended.
(1) Are any of the screws on the terminal block loose? If loose, tighten them.
(2) Is any abnormal noise heard from the servomotor bearings or brake section?
(3) Are any of the cables damaged or cracked? If the cables move with the machine, periodically
inspect the cables according to the working conditions.
(4) Is the core of the load coupling shaft deviated?
7-2

Service parts

A guide to the part replacement cycle is shown below. Note that these will differ according to the
working conditions or environmental conditions, so replace the parts if any abnormality is found.
Contact Mitsubishi branch or your dealer for repairs or part replacements.
Part name
Smoothing capacitor
Servo drive unit
Cooling fan
Battery
Bearings
Servomotor
Detector
Oil seal, V-ring
(1) Power smoothing capacitor : The characteristics of the power smoothing capacitor will deteriorate
(2) Relays
(3) Servomotor bearings
(4) Servomotor oil seal, V-ring : These parts should be replaced after 5,000 hours of operation at the
7. Maintenance
1. Before starting maintenance or inspections, turn the main circuit power and
control power both OFF. Wait at least ten minutes for the CHARGE lamp to
turn OFF, and then using a tester, confirm that the input and output voltage
are zero. Failure to observe this could lead to electric shocks.
2. Inspections must be carried out by a qualified technician. Failure to observe
this could lead to electric shocks. Contact your nearest Mitsubishi branch or
dealer for repairs and part replacement.
1. Never perform a megger test (measure the insulation resistance) of the
servo drive unit. Failure to observe this could lead to faults.
2. The user must never disassemble or modify this product.
Standard replacement time
10,000 to 30,000 hours
20,000 to 30,000 hours
20,000 to 30,000 hours
due to the effect of ripple currents, etc. The capacitor life is greatly
affected by the ambient temperature and working conditions.
However, when used continuously in a normal air-conditioned
environment, the service life will be ten years.
: Contact faults will occur due to contact wear caused by the
switching current. The service life will be reached after 100,000
cumulative switches (switching life) although this will differ according
to the power capacity.
: The motor bearings should be replaced after 20,000 to 30,000 hours
of rated load operation at the rated speed. This will be affected by
the operation state, but the bearings must be replaced when any
abnormal noise or vibration is found in the inspections.
rated speed. This will be affected by the operation state, but these
parts must be replaced if oil leaks, etc., are found in the inspections.
10 years
The standard replacement time is
a reference. Even if the standard
replacement time is not reached,
(2 to 3 years)
the part must be replaced if any
10,000 hours
abnormality is found.
5,000 hours
7 - 2
Remarks