Troubleshooting
Symptom
The Ethernet COLL LED is lit
solid.
354
What to do
Network collisions are bound to occur and are
normal. However, if this LED is lit solid, do the
following:
1 Check the physical network connection.
2 Verify that the Remote Office 9150 unit can be
pinged.
3 Check the network configuration (such as
routing, traffic load, and so on). Adjust the
network configuration, if required.
4 There should be no broadcast or multicast
activity on the telephony LAN (TLAN).
Interconnect a hub and a network analyzer to
the TLAN and monitor for such activity.
Identify the source(s) and isolate them from
the TLAN.