Diagnostics Using Starter - Siemens SINAMICS S120 Installation And Start-Up Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnosis

Diagnostics using STARTER

6.2
Diagnostics using STARTER
Description
The diagnostic functions support commissioning and service personnel during
commissioning, troubleshooting, diagnostics and service activities.
General information
Prerequisite: STARTER running online.
The following diagnostic functions are available in STARTER:
S PROFIBUS diagnostics buffer
The message output window shows the states of the control/status words,
parameters and drive enable signals for the selected drive/device.
S Fault/alarm display in the alarms output window
The faults and alarms for one or more drives/devices can be displayed. The
fault/alarm description is called up by selecting "Help –> Context" or by pressing
the SHIFT + F1 keys.
S Diagnostics overview
An overview table is displayed containing all the drives available in the project.
– Device: the available devices and drives are displayed with names; the
device status is output in the "device diagnostics" window.
– Operating status: the current operating status (e.g. OFFLINE, ONLINE,
COMMISSIONING, STOP, STOP U, RUN) of the device or drive is
displayed and can be controlled by means of the mode selection switch.
S Specifying signals with the ramp-function generator
See Subsection 6.2.1
S Signal recording with the trace function-
See Subsection 6.2.2
S Analyzing the control response with the measuring function
See Subsection 6.2.3
S Outputting voltage signals for external measuring devices via measuring
sockets
See Subsection 6.2.4
6-202
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents