Diagnosis
Messages – faults and alarms
External triggering of messages
If the appropriate binector input is interconnected with an input signal, fault 1, 2 or
3 or alarm 1, 2 or 3 can be triggered via an external input signal.
Once an external fault (1 to 3) has been triggered on the Control Unit drive object,
this fault is also present on all associated drive objects. If one of these external
faults is triggered on a different drive object, it is only present on that particular
drive object.
BI: p2106
BI: p2107
BI: p2108
BI: p2112
BI: p2116
BI: p2117
Note
An external fault or warning is triggered by a 1/0 signal.
An external fault and alarm do not usually mean that an internal drive message
has been generated. The cause of an external fault and warning should, therefore,
be remedied outside the drive.
6.3.4

Parameters and function diagrams for faults and alarms

Parameter overview (see List Manual)
S r0944
...
S p0952
S p2100[0...19]
...
S r2139
Function diagram overview (see List Manual)
S 1710
S 8060
S 8065
S 8070
S 8075
6-224
--> External fault 1
--> External fault 2
--> External fault 3
--> External alarm 1
--> External alarm 2
--> External alarm 3
Counter for fault buffer changes
Fault counter
Sets the fault number for fault response
Status word faults/alarms
Outline diagram - monitoring, faults, warnings
Faults and warnings - fault buffer
Faults and warnings - warning buffer
Faults and warnings - fault/warning trigger word r2129
Faults and warnings - fault/warning configuration
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
--> F07860(A)
--> F07861(A)
--> F07862(A)
--> A07850(F)
--> A07851(F)
--> A07852(F)
E Siemens AG, 2004. All rights reserved
J