Siemens SINAMICS S120 Installation And Start-Up Manual page 64

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
Initial commissioning using vector (booksize) as an example
Table 3-7
Commissioning sequence with STARTER (example), continued
What to do?
S
3.2. Enable Motor
Enable signals for the Motor Module (drive_1)
Module
p0840 = 722.0
p0844 = 722.1
p0845 = 1
p0848 = 722.2
p0849 = 1
p0852 = 722.3
3.3. Ramp-func-
Ramp-function generator
tion
p1140 = 1
generator
p1141 = 1
p1142 = 1
3.4. Setpoint
Specify setpoint
p1001 = 40
3-64
How to do it?
ON/OFF1
1st OFF2
2nd OFF2
1st OFF3
2nd OFF3
Enable operation
Enable ramp-function generator
Start ramp-function generator
Enable speed setpoint
Fixed speed setpoint 1
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Comments
See function diagram [2501]
See function diagram [3060]
See function diagram [3010]
E Siemens AG, 2004. All rights reserved