Response time for "Safe brake control" function
The following values can be specified for the response times when the function is
selected/deselected via input terminals:
S Typical response time
4 x safety monitoring clock cycle CU (r9780) + inputs/outputs sampling time
(p0799)
S Maximum response time that may occur in the event of a fault
8 x safety monitoring clock cycle CU (r9780) + inputs/outputs sampling time
(p0799)
Examples:
Assumption:
Safety monitoring clock cycle CU (r9780) = 4 ms and
inputs/outputs sampling time (r0799) = 4 ms
t
= 4 x r9780 (4 ms) + r0799 (4 ms) = 20 ms
R_typ
t
= 8 x r9780 (4 ms) + r0799 (4 ms) = 36 ms
R_max
Parameter overview (see List Manual)
S p0799
S r9780
S r9880