Commissioning

STARTER commissioning tool

3.2
STARTER commissioning tool
Brief description
STARTER is used for commissioning drive units in the MICROMASTER and
SINAMICS product ranges.
STARTER can be used for the following:
S Commissioning
S Testing
S Diagnostics
System requirements
The system requirements for STARTER can be found in the "read me" file in the
STARTER installation directory.
3.2.1

Important STARTER functions

Description
STARTER supports the following tools for managing the project:
S Copying from RAM to ROM
S Loading to target system
S Loading to PG
S Restoring the factory settings
S Commissioning Wizard
Copying from RAM to ROM
You can use this function to save volatile Control Unit data to the non-volatile Com-
pactFlash card. This ensures that the data is still available after the 24 V Control
Unit supply has been switched off.
This function can be activated as follows:
S Extras –> Setting –> Download –> Activate "Copy from RAM to ROM"
This means that every time you choose "Load project to target system", the
data is transferred to the non-volatile memory.
S Right-click Drive unit –> Target system –> Copy from RAM to ROM
S Drive unit grayed out –> "Copy from RAM to ROM" button
3-44
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition