CHAPTER 4. PREVENTATIVE MAINTENANCE AND

INTRODUCTION

MAINTENANCE RECORDS

DAILY MAINTENANCE

TROUBLESHOOTING
Maintenance on the steamer must be performed on a regular basis to
keep the unit running properly. Follow the maintenance instructions in
this chapter and problems will be kept to a minimum. If problems do
occur, refer to the Troubleshooting Guide on page 51. For more infor-
mation on products and services, contact your nearest Authorized Ser-
vice Representative.
Make a file solely for rnaintenance records and keep a written record of
daily, weekly, and yearly maintenance and when the steamer is
descaled. These records will protect warranty coverage and help
personnel to know when to perform maintenance functions.
1. Clean interior and exterior of SteamCraft V according to instructions of
SHUT DOWN an page 43, Operation.
2. Before draining, while water is still warm, brush the generator out with
a very soft brush going over the probes, elements and sides. This
removes scale before it hardens and prevents scale buildup. Drain
the steam generator at least twice a day in order to maintain the
quality of water being used. The more often water is drained from the
steam generator, the less scale builds up on the heating coils. If poor
quality water is used, the steam generator may nave to be drained
more often than twice a day. See Water Quality Requirements on
page 6.
3. Remove any spilled food from the steamer and ensure that drain
screen is clear. Wipe interior and door gasket with a damp cloth only.
Do not use soap or detergent inside steamer. Run clean rinse water
through compartment drain and steam generator.
4. The slide racks, fan guard, and steam generator cover can be
removed for thorough cleaning as necessary. Wash and rinse
separately or wash them in dishwasher.
5. Before cleaning steamer exterior, be sure that electricity is turned off
at the disconnect switch. Use a damp cloth for cleaning as
necessary. Never hose down the equipment.
CET-16 Service Manual