D1: Diagnostics tools
5.3 Service overview
Position actual value measuring system 1/2
The actual position of the axis as measured via measuring system 1/2. The position is displayed in the machine
coordinate system (no work offsets or tool offsets included).
Unit: mm, inch or degrees
Power section in i²t limitation HMI SW 6.3 and later
Limitation for protecting the power section against continuous overloading of the SIMODRIVE 611 drives.
2
State 1: i
t-power section limitation has responded
2
State 0: i
t power section limitation has not responded
Display is valid for SIMODRIVE universal and SIMODRIVE digital.
Display corresponds to NST DB31, ... DBX95.7
2
("i
t-monitoring").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Heatsink temperature warning
Warning signal output by drive:
State 0: The heat sink temperature monitoring has not responded.
State 1: The heatsink temperature monitoring has responded.
Display corresponds to IS DB31, ... DBX94.1
("Heatsink temperature prewarning").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Motor temperature warning
Warning signal output by drive:
State 0: The motor temperature is below the warning threshold.
State 1: The motor temperature has exceeded the defined warning threshold.
The warning threshold corresponds to the machine data:
MD1602 $MD_MOTOR_TEMP_WARN_LIMIT (maximum motor temperature).
Display corresponds to NST DB31, ... DBX94.0 ("Motor temperature prewarning").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
284