8-623 Regicon Data Overflow (A2 Patch Y)
At A2 patch detection, the YSO correction setting value of either Y, M, C, or K exceeds the set-
ting range (NVM value 0 to 474).
NOTE: Status Code not displayed on UI. Machine operation continues.
Procedure
Check the IBT Belt and Drum for a scratch or contamination. The check is OK.
Y
N
Replace as required.
Adjust the Color Registration
(ADJ
9.6).
Initial issue
DC 3535/2240/1632, WC M24
8-624 Regicon Data Overflow (Patch Magnification)
MAG Adjusted Set Point of operation results for each of Y,M,C exceeded the set range (NVM
value: 0~1432).
NOTE: Status Code not displayed on UI. Machine operation continues.
Procedure
Check the IBT Belt and Drum for a scratch or contamination. The check is OK.
Y
N
Replace as required.
Adjust the Color Registration
dC685 (ADJ
09/03
2-171
9.6).
Status Indicator RAPs