12-902 Power On H Transport Exit Sensor

The H Transport Exit Sensor detected a paper at power on, when all the Interlock were closed,
or at initialization.
Procedure
Enter
dC330
[012-104] and press Start. Actuate the H Transport Exit Sensor
display changes.
Y
N
Disconnect
P/J845
from Finisher Control PWB. Measure voltage at P/J845-B7. +5 VDC
is measured
(Figure
2).
Y
N
Replace Finisher PWB
(PL
17.13)
Check the wire from P/J845-B7 to P/J856-2 on the H Transport Exit Sensor for an open
circuit
(Figure
2). If the wire is good, replace the H Transport Exit Sensor
Check that the voltage at the customer outlet is in specification and does not drop during
machine start.
Figure 1 Component Location
Initial issue
DC 3535/2240/1632, WC M24
(Figure
(Figure
3).
(PL
17.4).
Exit
Sensor
1). The
Figure 2 12-902 RAP Circuit Diagram - H Transport Exit Sensor
09/03
2-285
Figure 3 Finisher PWB
Status Indicator RAPs