5-113 Registration Sensor Inversion
The document does not deactuate the DADF Registration Sensor 1500 msec after the Belt
Motor energized for document inversion.
Initial Actions
•
Ensure that the Platen Belt is properly aligned on the transport. Visually check the align-
ment of the Platen Belt with the registration guide on the rear edge of the Platen Glass
(PL
20.11). Align or replace the Platen Belt if necessary
•
Check the customer's documents to ensure they meet DADF specifications. Some docu-
ments, such as coated paper, have a high amount of adhesion and will not move freely
through the DADF. Documents over 105 gsm may cause this problem in the DADF.
•
Check/adjust the DADF Counterbalances
the Platen surround.
Procedure
Enter
dC330
[005-110] and press Start. Block the Registration Sensor
play changes.
Y
N
Go to the
5-702
Registration Sensor RAP.
Enter
dC330
[005-075] and press Start. The Registration Gate Solenoid energizes.
Y
N
+24 VDC is measured at P/J598-4 on the DADF Control PWB.
Y
N
Replace the DADF Control PWB
+24 VDC is measured at P/J598-5 on the DADF Control PWB.
Y
N
Go to
Flag 3
and
Flag
4. Check the wires for an open circuit. If the wires are good,
replace the Registration Gate Solenoid
Enter
dC330
[005-075]. Select Start. The voltage at J598-5 drops to less than +1.0
VDC.
Y
N
Replace the DADF Control PWB
Check the Registration Gate Solenoid linkage for binding. If the linkage is good, replace
the Registration Gate Solenoid
(PL
Enter
dC330
[005-056] (reverse) and press Start. Document Belt operates in reverse.
Y
N
Go to the
5-703
DADF Belt Motor RAP
Open the Document Feed Assembly and block the Registration Sensor with a sheet of paper.
The display changes.
Y
N
Go to the
5-702
Registration Sensor RAP
Check the following:
•
Duplex Rolls for contamination, wear and a rotation failure
Status Indicator RAPs
5-113
(PL
20.10).
(ADJ
5.2). Ensure that the DADF rests against
(PL
20.5). The
(PL
20.3).
(PL
20.2).
(PL
20.3).
20.2).
(PL
20.6).
•
Duplex Roll Drive for a mechanical load
•
Duplex Chute for deformation
•
Registration Roll for a transportation failure due to contamination, torn paper, or wear
20.8).
•
Document Transport Height
dis-
Figure 1 5-113 RAP Circuit Diagram - Registration Gate Solenoid
09/03
2-84
(PL
20.6).
(PL
20.7).
(ADJ
5.4).
Figure 2 DADF Control PWB
DC 3535/2240/1632, WC M24
(PL
Initial issue