Relay contacts of the REAL board
REAL
RK1
UK1
Relay
K1
AK1
RK2
Relay
UK2
K2
AK2
RK3
UK3
Relay
K3
AK3
RK4
UK4
Relay
K4
AK4
– 48 V,
max.
80 mA
GND
– 48 V,
max.
15 W
Figure 3-165
REAL - Relay Contacts (De-Energized) and MDFU Interfaces
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
X06
MDFU
02
10a
11 9a
31
9b
22
10b
13
11a
33
11b
13a
15
04
12a
24
12b
35
13b
06
14a
26
14b
16
4a
PFTASa/b = Line trunk module
46
4b
PFTALa/b = Trunk
PFTTLa/b = Subscriber line (telephone)
27
3a
PFTTSa/b = Subscriber board (SLA)
RK = Normally closed contact
48
2b
UK = Switch contact
AK = Normally open contact
Power supply for external applications
17
15a
(maximum 15 W): -48 V is available on
37
15b
backplane pins 17 + 37 (GND = pins 27 + 48)
if no REAL is available.
X06
MDFU
Boards for HiPath 3000
REAL
PFTASa
PFTASb
PFTALb
Relay
K5
PFTALa
Relay
K5
Cur-
rent
PFTTLb
sen-
sor
PFTTLa
PFTTSb
Relay
PFTTSa
K6
Relay
K6