Table 10-2 Floating Contacts On The Optipoint Acoustic Adapter - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

wclient.fm
Workpoint Clients
optiPoint 500
Table 10-2
Floating contacts on the optiPoint acoustic adapter
Pin
Assign-
ment
1
Free
2
"Busy" con-
tact
3
4
"Call" con-
tact
5
6
Free
10-28
Signals active telephone states:
handset lifted
Loudspeaker activated or headset active
These states can be displayed, for example, on external signaling equip-
ment (LED, relay, etc.) The signaling equipment must have its own power
supply.
The contact can be loaded with up to 5 W at 24 Vac or 60 Vdc.
Signals the call receipt state.
This can be used, for example, to control a secondary bell.
The contact can be loaded with up to 5 W at 24 Vac or 60 Vdc.
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual