Step
7.
Make the following settings in the ECGM tool:
File/Options menu: Select the service PC's COM interface (for example:
COM1)
File/Install Software menu: Select the file E1v0xx.pnm (for example,
E140ah.pnm from the directory ecginst.
File/Install Edb menu: Select the file Ecg_edbv.ein (for example
Ecg_edb4.ein) from the directory ecginst.
File/Update Site menu:
8.
Close the ECGM tool and then restart (ecgm.exe).
9.
Enter the COM interface under "COMM" and the customer name in the Set-
tings/ECG Name menu. All other windows are updated automatically.
10.
Channel configuration
Define the channel parameters in the View/Database menu (reserve unused
channels with "Out of Service".):
Protocol
Signaling method (incoming and outgoing)
Clock master (always central office)
Operator number (corresponds to the number of the attendant console of the
HiPath 3000)
11.
Software download
If the seven-segment display H1 on the TMCAS displays "H", it is necessary to
download the extender software (Download/Extender menu). Otherwise, con-
tinue with the next step.
12.
Start the software/database download using the Download/Software and
Database menu. This procedure takes approximately 8 minutes.
The download is complete when the configured channels display the "Idle" status.
The seven-segment display H1 on the TMCAS shows "A" (= active).
3-294
Under ECG SOFTWARE, select loadware file E1v0xx.pnm.
Under "ECG EDB", select file vbrazil.iyy.
Under "FILE NAME", select file extension .db for logging TMCAS events.
Enter the customer name under "ECG NAME".
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Activity
P31003-H3560-S403-54-7620, 09/05