Siemens HiPath 5000 Service Manual page 265

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

System configuration using SLCN
For information on the maximum possible system configuration of HiPath Cordless Office with
the SLCN boards see Table 11-1.
SLCN board distribution in HiPath 3800 cabinets
You can install up to four SLCN boards in HiPath 3800. A system cabinet can be fitted with all
four SLCN boards.
To guarantee uninterrupted operation of the HiPath 3800, not more than two SLCN
>
boards should be plugged in to a PCM segment. This condition must always be ob-
served. For information on PCM segment distribution, see Section 4.2.5.6.
One board slot should be kept free between two SCLN boards to prevent overheat-
ing.
Supplying power to base stations
Power is supplied to the base stations primarily via the internal PSU in the system in question.
If the correct number of LUNA2 modules was calculated, the system's internal power supply
unit provides sufficient power to supply the HiPath Cordless Office system configuration spec-
ified in Table 11-1.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3-175

Advertisement