Optipoint Acoustic Adapter - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

wclient.fm
Workpoint Clients
optiPoint 500
10.2.3.4

optiPoint Acoustic Adapter

The optiPoint acoustic adapter is used for connecting
a headset (121 TR 9-5) (see Section 10.7.2)
an active loudspeaker box and a desk microphone via the Y cable
busy display/door opener and secondary bell/light paging, etc. (each with its own power
supply) via floating contacts (not supported when using the adapter on optiPoint 410 and
optiPoint 420).
1
2
Figure 10-15
optiPoint Acoustic Adapter
Notes on the optiPoint acoustic adapter
Section 10.2.4 contains details on a possible additional external power supply.
The internal components of the optiPoint terminal are deactivated in speakerphone mode
if an external microphone and an external loudspeaker are used (sense lead).
optiPoint 500 basic does not support the connection of an external microphone to the op-
tiPoint acoustic adapter.
The speakerphone mode selection is independent of whether the internal or an external
speakerphone is used. External speakerphones have precedence over internal speaker-
phones with the exception of manual intercom and signaling procedures.
The internal microphone, the transmitter inset and any microphone connected to the opti-
Point acoustic adapter are muted in the "Mute" audio state.
10-26
Assignment of the three connection jacks:
1 Connecting a headset with the following electrical
values (121 TR 9-5):
3
2 Connecting a loudspeaker and microphone using Y
cable (see Figure 10-16)
3 Floating contacts (see Table 10-2), load capacity of
max. 5 W at 24 Vac or 60 Vdc
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Microphone (electret interface):
max. power: 400 µA,
supply voltage: 5 V ± 10%
series resistor: 5 kΩ ± 10%
Acoustic transformer:
Impedance: 150 Ω ± 10%
EBD: 13 dB ± 2.5 dB