Siemens HiPath 5000 Service Manual page 634

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Width of the peripheral boards
Peripheral boards are divided into
Wide boards requiring a slot 45 mm (1.75") wide:
TML8W with GEE8
Use a 45 mm slot even if you are not installing a GEE8 so that you can easily add a
GEE8 later.
TMDID8 (for U.S. only)
Narrow boards requiring a slot 30 mm (1.2") wide (= all other boards)
You can insert wide boards into a 30 mm (1.2") slot. but if you do so, you can no longer use the
slot to its right.
Caution
7
Always wear an antistatic wristband when working on the system (especially when
handling boards).
Initializing the Boards
The system software detects the boards in ascending order, starting with the lowest installation
position the first time the system starts up. The system initializes subscriber line circuits and
ports in the sequence indicated by the arrow (Figure 4-89).
The system activates all connected boards in the following situations:
The maximum configuration has not yet been reached. While sequentially scanning the
slots for each board, the system software checks whether the maximum number of stations
or trunks has been exceeded. If it has, the board is not activated. The board LED shows
the board's status.
At least one B channel on line trunk modules is available for the slot (only the available
number of B channels is activated).
4-156
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
P31003-H3560-S403-54-7620, 09/05