Advertisement

boards.fm
Boards for HiPath 3000
Peripheral Boards
Jumper settings
The X300 or X302 jumpers are used to set the TMS2 interface for the connection of this inter-
face to NT1. The following can be set:
symmetric line (120 ohms)
Use only pre-formed cables S30267-Z57-Axxx to guarantee problem-free operation
(length = 6 m (not available in Germany), 10 m or 20 m).
coaxial line (75 ohms)
S30267-Z69-Axxx.
TMS2
Interface
120 ohms =
factory default
75 ohms
SU connector assignment (backplane) and cable color codes
Table 3-155
TMS2 (Not for U.S.) - SU Connector Assignment and Cable Color Codes
SU connector
1
Xx8/Xx9
Pin
2
22
6
26
1
SU connector Xx8B is used in board status 4 and lower, whereas SU connector Xx9 is used in board status 5 and higher.
Note that the SU connector Xx9 was used in the old TMS2M board.
>
3-322
Jumper
X300
2 - 3
1 - 2
Function
a-wire (T), receive
b-wire (R), receive
a-wire (T), transmit
b-wire (R), transmit
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Jumper
Jumper
X301
X302
2 - 3
2 - 3
1 - 2
1 - 2
Cable S30267-Z57-Axxx, color code
Up to and including
status 6
grn
blk
red
blk
Status 7 or later
wht/blu
blu/wht
wht/ora
ora/wht
P31003-H3560-S403-54-7620, 09/05