YASKAWA E7U Programming Manual page 146

Industrial hvac drive
Table of Contents

Advertisement

Parameter
Parameter Name
No.
Digital Operator Display
PI Primary Delay Time
b5-08
Constant
PI Delay Time
PI Output Level Selection
b5-09
Output Level Sel
Denotes that parameter can be changed when the Drive is running.
PI Output Gain Setting
b5-10
Output Gain
PI Output Reverse Selection
b5-11
Output Rev Sel
PI Feedback Reference
b5-12
Missing Detection Selection
Fb los Det Sel
PI Feedback Loss Detection
b5-13
Level
Fb los Det Lvl
PI Feedback Loss Detection
b5-14
Time
Fb los Det Time
Sleep Function Start
b5-15
Level
Sleep Level
Sleep Delay Time
b5-16
Sleep Time
PI Accel/Decel Time
b5-17
Acc/Dec Time
PI Setpoint Selection
b5-18
PI Setpoint Sel
PI Setpoint Value
b5-19
PI Setpoint
PI Setpoint Display Scaling
b5-20
Setpoint Scaling
PI Sleep Input Source
b5-21
PI Sleep Source
b5-22
PI Snooze Level
Snooze Level
PI Snooze Delay Time
b5-23
Snooze Delay Time
PI Snooze Deactivation Level
b5-24
Wake-Up Level
PI Setpoint Boost Setting
b5-25
Setpoint Boost
PI Maximum Boost Time
b5-26
Max Boost Time
PI Snooze Feedback Level
b5-27
Snooze Feedback
Denotes that parameter can be changed when the drive is running. ** Range depends on b5-20 setting. Units depend on b5-31 setting.
Table A.1 Parameter List (Continued)
Description
Sets the amount of time for a filter on the output of the PI
controller.
Determines whether the PI controller will be direct or reverse
acting.
0: Normal Output (direct acting)
1: Reverse Output (reverse acting)
Sets the output gain of the PI controller.
0: 0 limit (when PI output goes negative Drive stops)
1: Reverse (when PI goes negative Drive reverses)
0 limit automatic when reverse prohibit is selected using b1-04
0: Disabled
1: Alarm
2: Fault
Sets the PI feedback loss detection level as a percentage of
maximum frequency (E1-04).
Sets the PI feedback loss detection delay time in terms of seconds.
Sets the sleep function start frequency.
Sets the sleep function delay time in terms of seconds.
Applies an accel/decel time to the PI setpoint reference.
0: Disabled
1: Enabled
*Depends on b5-20.
Set display/setting unit of b5-19, U1-24, and U1-38.
Input Source Selection for Sleep function Mode.
0: PI Setpoint
1: SFS Input (This is near the PI Output)
2: Snooze
Sets the PI snooze function start level as a percentage of maximum
frequency (E1-04).
Sets the PI snooze function delay time in terms of seconds.
When the PI feedback drops below this level, normal PI operation
starts again. Set as a percentage of maximum frequency (E1-04).
Temporary increase of PI setpoint to create an overshoot of the
intended PI setpoint.
Sets a time limitation for reaching temporarily boosted PI setpoint
(intended PI setpoint + b5-25).
PI snooze mode will be activated when PI feedback is above this
level. Set as a percentage of maximum frequency (E1-04).
Parameters A - 6
Setting
Factory
Menu
Range
Setting
Location
0.00 to
0.00sec
Programming
10.00
0 or 1
0
Programming
0.0 to 25.0
1.0
Programming
0 or 1
0
Programming
0 to 2
0
Programming
0 to 100
0%
Programming
0.0 to 25.5
1.0sec
Programming
0.0 to 200.0
0.0Hz
Programming
0.0 to 25.5
0.0sec
Programming
0.0 to 25.5
0.0sec
Programming
0 or 1
0
Programming
0.00 to
0.00%
Programming
100.00**
0 to 39999
1
Programming
0 to 2
1
Programming
0 to 100
0%
Programming
0 to 3600
0sec
Programming
0 to 100
0%
Programming
0 to 100
0%
Programming
0 to 3600
0sec
Programming
0 to 100
60%
Programming

Advertisement

Table of Contents
loading

Table of Contents