Appendix A - Parameter List; Analog Outputs - YASKAWA E7U Programming Manual

Industrial hvac drive
Table of Contents

Advertisement

Parameter
Parameter Name
No.
Digital Operator Display
Terminal FM Monitor Selection
H4-01
Terminal FM Sel
H4-02
Terminal FM Gain Setting
Terminal FM Gain
H4-03
Terminal FM Bias Setting
Terminal FM Bias
Terminal AM Monitor Selection
H4-04
Terminal AM Sel
H4-05
Terminal AM Gain Setting
Terminal AM Gain
Denotes that parameter can be changed when the Drive is running.
Table A.1
Parameter List (Continued
Description

Analog Outputs

Selects which monitor will be output on terminals FM
and AC.
1: Frequency Ref (100% = max. output frequency)
2: Output Freq (100% = max. output frequency)
3: Output Current (100% = Drive rated current)
6: Output Voltage (100% = 230V or 100% = 460V)
7: DC Bus Voltage (100% = 400V or 100% = 800V)
8: Output kWatts (100% = Drive rated power)
15: Term A1 Level
16: Term A2 Level
18: Mot SEC Current (100% = Motor rated secondary
current)
20: SFS Output (100% = max. output frequency)
24: PI Feedback
31: Not Used
36: PI Input
37: PI Output (100% = max. output frequency)
38: PI Setpoint
51: Auto Mode Fref (100% = max. output frequency)
52: Hand Mode Fref (100% = max. output frequency)
53: PI Feedback 2
NOTE: 100% = 10V DC output * FM gain setting
(H4-02).
Sets terminal FM output voltage (in percent of 10V)
when selected monitor is at 100% output.
Sets terminal FM output voltage (in percent of 10V)
when selected monitor is at 0% output.
Selects which monitor will be output on terminals AM
and AC.
1: Frequency Ref (100% = max. output frequency)
2: Output Freq (100% = max. output frequency)
3: Output Current (100% = Drive rated current)
6: Output Voltage (100% = 230V or 100% = 460V)
7: DC Bus Voltage (100% = 400V or 100% = 800V)
8: Output kWatts (100% = Drive rated power)
15: Term A1 Level
16: Term A2 Level
18: Mot SEC Current (100% = Motor rated secondary
current)
20: SFS Output (100% = max. output frequency)
24: PI Feedback
31: Not Used
36: PI Input
37: PI Output (100% = max. output frequency)
38: PI Setpoint
51: Auto Mode Fref (100% = max. output frequency)
52: Hand Mode Fref (100% = max. output frequency)
53: PI Feedback 2
NOTE: 100% = 10V DC output * AM gain setting
(H4-05).
Sets terminal AM output voltage (in percent of 10V)
when selected monitor is at 100% output.
Parameters A - 17
)
Setting
Factory
Range
Setting
1 to 53
2
0.0 to
100.0%
1000.0
–110.0 to
0.0%
110.0
1 to 53
8
0.0 to
50.0%
1000.0
Menu
Location
Programming
Programming
Programming
Programming
Programming