The digital operator will not display which parameters did not match, only that the verification found discrepancies in some
parameter values.
NOTE: In order to properly use the COPY or VERIFY functions, the following Drive specifications must be identical
between the Drive that the parameters were read from and the Drive that the parameters are to be written to:
Model Number (e.g. CIMR-E7U2015)
Software Number (e.g. 03011 also known as FLASH ID)
Yaskawa offers DriveWizard™ software that can also READ, COPY, and VERIFY Drive parameter values. DriveWizard™
lists all discrepancies between the Drive and a pre-saved parameter file when verifying is performed.
DriveWizard first select o2-15= "0: Disabled" and select o2-06= "0: Disabled" then remove the digital operator/keypad
To use
and attach the DriveWizard cable in its place.
-ADV-
VYE
VERIFY ERROR
Programming 132