R50/60CV1A
4.2

Removal of Electrical Parts Box

Procedure
Step
Remove the wire
1
harness connectors
from the PCB.
Dismount the
outdoor
2
air thermistor
and the
heat exchanger
thermistor.
176
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Si01-406
Points
Removal Procedure