3. Removal of Electrical Box / PCB

Procedure
Step
1. Remove the right side
panel.
1
Unhook the outdoor
temperature thermistor.
2
Remove the 2 screws
and remove the
terminal cover.
Remove the screw and
3
remove the stop valve
cover.
4
Remove the screws
and disconnect the
connecting wires.
Remove the 3 screws
5
and remove the wire
clamp.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Outdoor temperature thermistor
Removal of Electrical Box / PCB
Preparation
Remove the panels
according to the "Removal
of Outer Panels".
(R14867)
Terminal cover
Stop valve
cover
(R14868)
(R14869)
Wire clamp
(R14870)
Points
7