Removal Of Bellmouth And Left Side Plate - Daikin FT25CV1A Service Manual

C-series
Hide thumbs Also See for FT25CV1A:
Table of Contents

Advertisement

Si01-406
3.2

Removal of Bellmouth and Left Side Plate

Procedure
Step
The bellmouth is
1
attached with two
screws and four hooks.
Remove the two screws
2
and pull the bellmouth
forward to remove, as
the four hooks are
provided.
3
The rib is equipped on
the left side plate and it
can be disengaged
when the one fixed
screw is removed.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
R25/35CV1A, RY25/35CVMA
Points
Remove the bellmouth,
beginning the front plate
after removing the two
screws which are set below.
Slide the bellmouth in the
arrow direction to disengage
the hook B.
167