Functions of Heat Pump Models
Inverter Features
The inverter provides the following features:
Frequency Limits
The following table shows the functions that define the minimum and maximum frequency:
Low
High
Forced Cooling
For more information, refer to "Forced operation mode" on page
Operation
30
The regulating capacity can be changed according to the changes in the outdoor air
temperature and cooling / heating load.
Quick heating and quick cooling
The compressor rotational speed is increased when starting the heating (or cooling). This
enables a quick set temperature.
Air discharge
temperature
45˚C
Start
Even during extreme cold weather, the high capacity is achieved. It is maintained even when
the outdoor air temperature is 2°C.
Comfortable air conditioning
A detailed adjustment is integrated to ensure a fixed room temperature. It is possible to air
condition with a small room temperature variation.
Energy saving heating and cooling
Once the set temperature is reached, the energy saving operation enables to maintain the
room temperature at low power.
Frequency limits
Four way valve activating guarantee. Refer to page 42.
Input current control. Refer to page 43.
Compressor protection function. Refer to page 42.
Heating peak-cut control. Refer to page 44.
Freeze-up protection control. Refer to page 43.
Defrost control. Refer to page 46.
inverter
normal heat pump
60
120
Limited during the activation of following functions
Si01-406
seconds
300
(R1187)
.
48
Functions and Control