FT50/60CV1A
Step
3. Remove the
fan
motor.
Remove the fan rotor.
1
4. Remove the bearing.
Remove the fan rotor.
1
The bearing is on the
left side.
2
Loosen the two screws
and remove the
mounting plate for the
bearing.
3
The bearing is made of
rubber. Push it inwards
firmly and remove it.
164
Procedure
Si01-406
Points
Reassembling the fan motor
(1) When reassembling the fan
rotor, provide as much as
5mm of play between the
side face of the rotor and the
bottom frame.
Side face of
Side face of rotor
bottom frame
5mm
(2) When reassembling the fan
motor, align the end of the
connector with the height of
#
for play.
Removal Procedure
(R2808)