Si01-406
Step
4
Disengage the hooks of
the pipe retainer on the
back.
5
Pull auxiliary pipe
forward to an angle of
10 to 20 degrees.
Disengage hooks
6
located right and left
side, and pull heat
exchanger forward.
The hooks are
symmetrically placed in
the right and the left.
Removal Procedure
Procedure
FT25/35CV1A, FTY25/35CVMA
Points
Be careful to prevent pipe
deformation.
Lift the heat exchanger
slightly upward to the right,
and the left hook comes to
be disengaged easily.
141